Software Name:
Modbus OPC server
Version: 2.3
Category: Miscellaneous
Date Listed/Updated: 2022-11-30 15:10:31
File size: 7721 KB
OS: Win2000,WinXP,Win7 x32,Win7 x64,Windows 8,Windows 10,WinServer,WinOther,WinVista,WinVista x64
License: Other Price($): 280
Author/Publisher name: Dmitry Shutin

View Full Screenshot
Description: The OPC server provides the OPC clients (any advanced SCADA systems) with an access to devices, supporting the MODBUS protocol.
To have a trial run of the software product, you can use, absolutely free of charge, 30 tags without any time limit. To handle more than 30 tags, you can use a 30-day fully functional trial period.
Key functions
Supported protocols: MODBUS RTU, MODBUS TCP, MODBUS ASCII
Supported MODBUS functions: 1,2,3,4,5,6,15,16
Supported communication channels: COM port, TCP connection
Opportunity to use an extended list of communication channel types (CSD, GPRS, etc.), using the Modem Communication Channel Module special software
Opportunity to poll tag groups of the device at varying intervals
Interaction with the OPC clients in accordance with the OPC DA specifications, version 2.05a
Service operation function (Windows OS Service)
Group setting of tags
Configuration import export in the CSV format (with a report file formatting)
Ability to survey and view tag values without the OPC client connection
Ability to operate at a broadcast address
Ability to emulate tag values
OPC server operation logging.
Features
Automatic search for connected devices reduces the configuring time.
Configuration import export into the CSV format significantly accelerates the configuring process.
Polling tag values of the device at varying intervals increases the speed of reading of critical parameters.
Surveying and viewing tag values without the OPC client connection allows the OPC server to be initially set without application of any additional software.
Tag value emulation provides the opportunity to debug projects in the upper level systems without any physical access to metering instruments.
We have affiliation with number one software market place Share-IT\. Contact us for better pricing/customised coupon code
Use Avangate Coupoun code 548AAC3EB7 to get maximum discount. Please contact through skype: softrevu or send mail to submit@softrevu.com for better pricing
EULA

Tags: Modbus OPC server Modbus software Modbus server Modbus RTU Modbus TCP Modbus ASCII OPC via Modbus
Is this software spam? Report Spam
Software removal request by publisher Removal Request
Software Review: Modbus OPC server Review
For publisher: Request Software Confirmation
Press release from the publisher:The OPC server provides the OPC clients (any advanced SCADA systems) with an access to devices, supporting the MODBUS protocol.
To have a trial run of the software product, you can use, absolutely free of charge, 30 tags without any time limit. To handle more than 30 tags, you can use a 30-day fully functional trial period.
To work in full mode, run the software ON THE TARGET COMPUTER and send the registration code and the remaining fields are filled in the registration dialog box at support@krug2000.com. We will send a response letter registration key FOR THIS COMPUTER.
Key functions
Supported protocols: MODBUS RTU, MODBUS TCP, MODBUS ASCII
Supported MODBUS functions: 1,2,3,4,5,6,15,16
Supported communication channels: COM port, TCP connection
Opportunity to use an extended list of communication channel types (CSD, GPRS, etc.), using the Modem Communication Channel Module special software
Opportunity to poll tag groups of the device at varying intervals
Interaction with the OPC clients in accordance with the OPC DA specifications, version 2.05a
Service operation function (Windows OS Service)
Group setting of tags
Configuration import export in the CSV format (with a report file formatting)
Ability to survey and view tag values without the OPC client connection
Ability to operate at a broadcast address
Ability to emulate tag values
OPC server operation logging.
Modbus OPC server-screenshot
Automatic search for connected devices reduces the time required for arranging a hard-wired connection of devices to the computer as well as for configuring the OPC server.
Configuration import export into the CSV format (with the possibility of its further editing and processing in Excel) significantly accelerates the configuring process.
Polling tag values of the device at varying intervals increases the speed of reading of critical parameters by reducing the frequency of reading of less important (or rarely changing) parameters.
Surveying and viewing tag values without the OPC client connection allows the OPC server to be initially set (parameter register number setting, etc.) without application of any additional software as well as to diagnose potential problems in the automated system development by separating the SCADA level errors and the device survey errors.
Tag value emulation provides the opportunity to debug projects in the upper level systems without any physical access to metering instruments, to emulate critical values for testing upset situations, and to easily create educational projects for different purposes.
Visit the Press Release for more details
Software from the publisher:Modbus OPC server,